GridFit
On-grid PV system design ยท SERA regulations
LV ยท 1 account

On-grid PV design that passes the rules before it reaches the utility

Small-scale PV is capped per connection point, not per site. GridFit designs an independent system for every meter, holds each one to its mandatory SERA ceiling, and derives production from real irradiation data transposed onto your actual tilt and orientation โ€” then rolls the whole set up into one coverage and payback picture.
MV ceiling 2 MWac per connection point LV fixed 15% of the meter's transformer ๐Ÿ”’ yield from plane-of-array irradiation, not flat PSH

1 Grid connection

๐Ÿ”’ 15% of transformer kVA SERA regulation
not adjustable

2 Site & irradiation

Built-in data is NASA POWER 20-year monthly climatology (2001โ€“2020) at 13 reference sites; the nearest one to your coordinates is used. To use Global Solar Atlas instead, export the monthly GHI for your point and paste it above โ€” it overrides the built-in set and is credited as such in the report.
The satellite view (below, in the results column) is fetched live for these coordinates โ€” no upload needed. The free public imagery service has a zoom ceiling around 200 m across; below that it returns a blank image, which is why the coverage field won't go tighter.

3 Array orientation

Plane-of-array irradiation is computed with the HDKR anisotropic sky model at 10-minute steps on the representative day of each month, so tilt and azimuth genuinely move the yield. A dual (Dom) array splits capacity between two opposing azimuths and sums their separate yields.

4 Accounts & consumption 1 meter

๐Ÿ“Ž next to a month attaches that bill (image or PDF). Files stay in this browser tab only โ€” nothing is uploaded โ€” and print into the report appendix.

5 System & tariff category

Category tariffs and the net billing sale price are the SEC/SERA schedule in SAR โ€” keep currency set to SAR for the figures to be correct. The load profile shapes each month's billed kWh across the 24 hours of a representative day so self-consumption and export are only credited when production and consumption actually overlap โ€” production after sunset never offsets an evening peak, no matter the monthly total. Coverage target, tariff category and load profile can all be overridden per account inside each tab.

6 Financial feasibility

CAPEX and O&M drive the feasibility table and ROI curve in the results column. Leave the cost per Wp blank to size the system without a financial analysis.

7 Report details

Both logos appear on the report's cover page alongside the company/client names โ€” leave either blank to omit it.
Billed consumption Estimated solar production
Cumulative net cash flow โ€” all accounts
The report is issued as PDF. Word export is restricted โ€” it requires the release key.
v1.0.0